Built-in maximum power tracking algorithm can significantly improve the energy utilization efficiency of photovoltaic system,
which is 15%~20% higher than traditional PWM charging efficiency.
Multiple tracking algorithms combined to accurately track the optimal working point of the I-V curve in a very short time
MPPT tracking efficiency can reach up to 99.9%.
Parameter name |
Parameter value |
Model |
ML4860 |
System voltage |
12V/24/36V/48V Auto |
Load loss |
0.7 W to 1.2 W |
Battery voltage |
9~70 |
Solar maximum input voltage |
145V (25 ° C) 130V (-25 ° C) |
Maximum power point voltage range |
Battery voltage +2V ~ 120V |
Rated charging current |
60A |
Rated load current |
20A |
Maximum capacitive load capacity |
10000uF |
PV system maximum input power |
800W/12V; 1600W/24V; 2400W/36V; 3200W/48V |
Conversion efficiency |
≤98% |
MPPT tracking efficiency |
>99% |
Temperature compensation coefficient |
-3mv/°C/2V (default) |
Operating temperature |
-35°C to +45°C |
Protection level |
IP32 |
Weight |
|
Way of communication |
RS232 RS485 |
Altitude |
≤ 3000 meters |
Product Size |
285*205*93mm |